Buffer size in k, Poll character, Poll response – Printronix N7000 H-Series Cartridge Ribbon Printer User Manual

Page 78: Idle response, One char enquiry

Advertising
background image

78

Chapter

4

HOST INTERFACE

Buffer Size in K

This option configures the amount of memory allocated for the serial port
buffer. You may specify between 1 and 16 Kbytes, in 1-Kbyte increments.

The default is 16K.

NOTE:

H-Series products have a range of 1 to 256 and a default of 64K.

If you select a baud rate that is 19200 or greater, you may need to
increase the Buffer Size in K parameter to improve performance.

Poll Character

This option is for the Series1 protocol. Whenever the printer receives this
character, it sends a response to the host indicating the current state of the
printer (see Series1 protocol). It may be configured from 0 through FF
hexadecimal.

Poll Response

This option is for the Series1 protocol. After receiving a poll character, the
printer will wait the poll response time in milliseconds before sending the
response. It may be configured from 0 through 30.

Idle Response

This option is for the Series1 protocol.

Disable

(default)

Enable

. The printer will send a response character every two seconds

while the number of valid bytes in the buffer is less than 75 percent of the
buffer size.

One Char Enquiry

The One Char Enquiry mode uses the Poll Character to detect a request from
the host and sends a response back to the host. This option also allows you to
turn on and off this feature.

The Poll Character is removed from the data stream. If the Data Protocol is
set to ETX/ACK, ACK/NAK, or Series 1, One Char Enquiry is automatically
disabled.

Table 4. One Char Enquiry Response Characters

Printer State

Response (hex)

Online and Buffer Not Full

22

Online and Buffer Full

23

Offline and Buffer Not Full

20

Offline and Buffer Full

21

Advertising