Sensor terminations in control panel, Electrical installation – Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-1895 User Manual
Page 17
![background image](/manuals/277877/17/background.png)
3. Electrical Installation
PNEG-1895 V2 Electronic Distributor Control
17
Sensor Terminations in Control Panel
Figure 3I
Placing a wire into the terminal block.
NOTE: Insulation must be removed from the end of the wire for a good connection.
1. Insert a small screw driver into the square opening under the terminal.
2. Push down on the small screw driver.
3. Insert the wire into the open terminal block above the small screw driver.
4. Remove the small screw driver to secure the wire.
5. Repeat for remaining wires.
Wire Connections for Terminal Block
Terminal Block #
Wire Connection
1
Shield
2
Black
3
White
4
Red
5
Green
6
Orange
7
Blue
8-11
Used for Safety Interlocks
NOTE: #11 Not shown here.
1. Sensor terminal block
2. Push in screw driver
3. Push down on screw driver
4. Insert wire into open terminal