6. Retrofit Installation
42
PNEG-1895 V2 Electronic Distributor Control
Sensor Plate Angle and Proximity Sensor Bracket Installation
Assemble the sensor plate angle (DEC0014) (A) to the proximity sensor bracket (DEC0006) (D) using
three (3) 1/4"-20 x 3/4" HHCS bolts (S-1429) (B) and 1/4"-20 nylock nuts (S-7025) (C) as shown in
Attach the proximity sensor bracket (DEC0006) (D) to the inside of the enclosure (DEC0005) (E) using
three (3) 1/4"-20 x 3/4" HHCS bolts (S-1429) (B) and 1/4"-20 nylock nuts (S-7025) (C).
Bracket must be installed with note markings facing down.
Figure 6C Sensor Plate Angle and Proximity Sensor Bracket
Ref #
Part #
Description
A
DEC0014
Sensor Plate Angle
B
S-1429
1/4"-20 x 3/4" HHCS Bolt
C
S-7025
1/4"-20 Nylock Nut
D
DEC0006
Proximity Sensor Bracket
E
DEC0005
Enclosure