PNEG-1895 V2 Electronic Distributor Control

7. Troubleshooting

Error Messages

Figure 7A

Cause: When using the supplied interlock function, this message will appear when a move is attempted
while the contact closure that indicates that upstream equipment is running is closed. The move will
complete once the contact closure opens indicating the upstream equipment is no longer running.

Figure 7B

Cause: This message will appear if the user attempts to move to the position where the distributor is
currently located. If a different position is desired, the user must select a different position.

Figure 7C

Cause: This message will appear if the user attempts to move to a position that has been configured as
“locked-out.” If this position is desired, it must first be unlocked by navigating to “Position Lock-Out” screen
in the setup menu.