6. Retrofit Installation

PNEG-1895 V2 Electronic Distributor Control

43

Proximity Sensor Location and Installation

NOTE: The location of the proximity sensor will be determined by the configuration of the distributor.
Using the table shown in

Figure 6D

, locate the diameter and number of spouts of the distributor being

used and note the proximity sensor reference number. This reference number is marked on the bottom
of the proximity sensor bracket (DEC0006) (B) and identifies the location for installing the proximity
sensors (DEC0107) (A).

Install the two (2) proximity sensors (DEC0107) (A) into the proximity sensor bracket (DEC0006) (B) at the
appropriate locations determined from the table.

(See Figure 6D below

and Figure 6E on Page 44.)

Figure 6D Proximity Sensor Location

Ref #

Part #

Description

A

DEC0107

Proximity Sensor

B

DEC0006

Proximity Sensor Bracket

Diameter # Spouts Prox Ref #

6

4

2

6

5

8

6

8

6

5

8

7

10

9

10

6

4

8

10

10

9

12

4

1

6

3

8

8

10

9

14

4

1

6

3

8

8