7 | Troubleshooting

Performance Series User’s Guide

156

Printhead Hot

The printhead too hot or is faulty.

Allow to cool or contact your technical
support representative.

There may be a poor cable connection. Contact your technical support

representative.

FPGA Hardware

The main controller board may be
faulty.

Ensure the latest software update has
been performed.

NV RAM Hardware

The main controller board may be
faulty.

Contact your technical support
representative.

PAPER Sensor
Blocked

Adhesive, dirt or remnants of a label
may be covering the sensor.

1. Clean the debris from the sen-

sor.

2. Perform “Calibrate Sensors”

calibration.

The main controller board may be
faulty.

Contact your technical support
representative.

The Top-of-Form sensor failed the
“Calibrate Sensors” calibration due to a
faulty sensor.

Contact your technical support
representative.

Paper Calibration

The wrong Top-of-Form sensor side
may have been selected and not able
to read media characteristics.

1. Ensure the Top-of-Form has

been set correctly.

The characteristics of the media may
not be sensed by the printer. (Ex. gap,
notch, mark)

1. Set the paper mode to continu-

ous.

2. Install different media.

No Top-of-Form
Found

The gap or mark was not found.

1. Ensure the Top-of-Form has

been set correctly.

2. Install different media.

The label image size exceeded the
maximum of 99 inches.

1. Check the print mechanism for a

paper jam.

2. Calibrate the printer for the

media being used.

There may be dirt or debris obstructing
the Top-of-Form sensor.

1. Clean the debris from the sen-

sors.

2. Perform “Calibrate Sensors”

calibration.

GPIO Hardware

There may be a poor connection to the
GPIO logic board.

Contact your technical support
representative.

The GPIO logic board may be faulty.

Contact your technical support
representative.

Present Sensor
Hardware

There may be a poor connection.

Perform the Present Sensor test.

The Present Sensor module may be
faulty.

Perform the Present Sensor test.

Symptom

Causes

Solutions