Menu System | 4
117
Performance Series User’s Guide
Note:
Narrow labels may slip during backup if the head pressure is set too high.
4. Tools
Select from the following options to adjust the appropriate settings:
•
Calibrate
•
Security
•
Maintenance
•
User Files
•
Date/Time
Calibrate
The Calibrate settings include:
•
Calibrate Sensors
•
Calibrate Paper
•
Calibrate Manually
•
Calibrate Display
a. Calibrate Sensors
Select Calibrate Sensors to automatically calibrate the printer without print media.
Calibration includes changes to the following settings:
•
Head Pressure (not applicable for the p1115)
•
Auto Load Sensor
•
Top-of-Form Sensor
Note:
The print media must be removed and the printhead mechanism must be
unlatched for the Calibrate Sensors to properly calibrate the printer.
b. Calibrate Paper
When selecting Calibrate Paper, the paper is scanned to determine the top-of-form
media and top-of-form gap settings.
Head Pressure Adjust
-5 to 5
0
Rewinder Tension Adjust
-10 to 10
0
Ribbon Tension Front Adjust
-10 to 10
0
Ribbon Tension Rear Adjust
-10 to 10
0
Present Distance Adjust
-100 to 100
0
Cut Distance Adjust
-100 to 100
0
Adjustment Settings
Ranges
Default