4 | Menu System

Performance Series User’s Guide

120

Secure - When the “Secure” option is selected, changes to the advanced settings

and user tools will require a password.

Secure All - When the “Secure All” option is selected, changes to any settings will

require a password.

3 Button Display - When this option is selected, the three button display will be

enabled on the main panel. A password will be needed to access the menu again.

Note:

The factory default password is the number “0.”

Note:

By default, security should be disabled.

Remove Security

To remove security, select the lock icon to the right of the Change Password utility. Type
your password and then select the green Accept button. To confirm, select the green
Accept button.

Maintenance

To adjust the following Maintenance settings, select the Maintenance button. The
maintenance settings include:

Cleaning

Upgrade

Odometers

a. Cleaning

Cleaning should be routinely performed. The maintenance alarm is set by the user in
thousands of inches.

Enter the desired maintenance reminder interval. Once a fault appears directing the user
to clean the printhead, insert a factory approved cleaning card under the printhead and
select Clean Now.

The Elapsed field displays the number of inches, in thousands, since the last cleaning.

Table 20: Maintenance Settings

b. Upgrade

The Upgrade function allows the user to upgrade the printer software. Insert a mass
storage device into the USB host with the appropriate file to be uploaded and then select
Upgrade.

Maintenance Settings

Ranges

Actions

Default

Maintenance

0k to 1000k in.

0 (never)

Clean Now

Select Clean Now