Viewing a spectrum table, Waveform viewing options – E-Mon E-PS-S-HV-RTU User Manual

Page 182

Advertising
background image

Chapter 9 Viewing Files and Reports

Viewing Waveforms

182

PowerSmart Socket Power Quality Meter

3. Check the Enabled box to visualize harmonic faults on

the spectrum graph and in harmonic tables.

Harmonics that exceed selected compliance levels are colored
in red on the graph and in the tables.

Viewing a Spectrum Table

Click on the

button on the local toolbar to display the

harmonics spectrum in a tabular view for a selected phase or
for all phases together.

The spectrum table shows voltage, current, active power and
reactive power harmonic components both in percent of the
fundamental and in natural units, and harmonic phase
angles.

To change a phase, click on the window with the right mouse
button, select “Options...”, check the phase you want

Waveform Viewing Options

See

Working with Graphic Windows

for more information on

working with waveforms.

Viewing Phasor Diagrams

The phasor diagrams show you relative magnitudes and
angles of the three-phase voltage and current fundamental
component. All angles are shown relative to the reference
voltage channel.

To change the reference channel, click on the waveform
window with the right mouse button, select “Options...”, click
on the “Phasor” tab, check the channel you want to make a
reference channel, and then click “OK”.

Advertising
This manual is related to the following products: