6.3.4. RESETTING TO THE AXIS FACTORY DEFAULTS
Restoring the Factory Default Settings is used when the previous steps do not
resolve problems with the Camera Unit.
1. Disconnect the
POWER CABLE
from the Camera unit.
2. Remove the two (2) Torx screws,
holding the camera into place with a
T20 ALLEN KEY
.
3. Flip the camera over to reveal the
control components on the bottom.
4. Reconnect the Power Cable
.
– Wait
approximately
fifteen (15) seconds
until the NET and PWR
led lights are
orange.
5. Press and hold the
RESET
button for approximately thirty (30) seconds until
the
NET
led light flickers green, then release
RESET
button.
– Doing this resets the Factory Defaults.
6. Reassemble the Camera Unit and follow
STEPS 1-16
from SECTION 11.2. and
11.2.1.
to complete the programming process.
TORX Screws
RESET NET PWR
SWITCH LED LED