2.3. PROPER SHUTDOWN PROCEDURE









1. An external keyboard must be used to perform the shutdown.

2. Press the

ALT + F5

key to begin the shut-down process from the weight

processing screen..

– A

Shut Off Warning

appears whenever

ALT + F5

is pushed.

3. After proper shut-down is complete, ALWAYS turn off the

internal

power switch.

– Until the FB2550 DAT AC power is turned off from the inside cabinate power
– switch, it will continue to supply operating voltage to the instrument circuits.

4. The

POWER-OFF (ALT + F5)

is inactive when any Service Programming is

being completed.

C A U T I O N

FB2550 DAT must be shut down properly!

Failure to shut down properly can result in corrupting essential
software files necessary for proper operation, and may require
replacement of the 8GB Flash Drive.