D. fieldbus data representation, continued – Fairbanks FB2550 DAT SERIES DRIVER ACCESS TERMINAL User Manual

Page 138

Advertising
background image

Appendix I: Fieldbus Interface Reference Data

2/2013

138

51303 Rev. 1

D. FIELDBUS DATA REPRESENTATION, CONTINUED

WORD

BYTE

REGISTER

USAGE

SIZE(BYTES) SCALE

20

40

-

41

Status

Word

0

2 Scale 2

21

42

-

43

Status

Word

1 2

22

44

-

45

Status

Word

2 2

23

-

24

46

-

49

Unassigned

4

25

-

26

50

-

53

Gross

Weight 4

27

-

28

54

-

57

Tare

Weight

4

29

-

30

58

-

61

Net

Weight 4

31

-

32

62

-

65

Setpoint

1 4

33

-

34

66

-

69

Setpoint

2 4

35 - 36

70 - 73

Flow Rate (weight /second) 4

37

-

39

74

-

79

Unassigned

6

40

80

-

81

Status

Word

0

2 Scale 2

41

82

-

83

Status

Word

1 2

42

84

-

85

Status

Word

2 2

43

-

44

86

-

89

Unassigned

4

45

-

46

90

-

93

Gross

Weight 4

47

-

48

94

-

97

Tare

Weight

4

49 - 50

98 – 101 Net Weight

4

51 - 52

102 - 105

Setpoint 1

4

53 - 54

106 - 109

Setpoint 2

4

55 - 56

110 - 113

Flow Rate (weight /second) 4

57

-

59

114

-

119

Unassigned

6

Advertising