D. fieldbus data representation, continued – Fairbanks FB2550 DAT SERIES DRIVER ACCESS TERMINAL User Manual
Page 138

Appendix I: Fieldbus Interface Reference Data
2/2013
138
51303 Rev. 1
D. FIELDBUS DATA REPRESENTATION, CONTINUED
WORD
BYTE
REGISTER
USAGE
SIZE(BYTES) SCALE
20
40
-
41
Status
Word
0
2 Scale 2
21
42
-
43
Status
Word
1 2
22
44
-
45
Status
Word
2 2
23
-
24
46
-
49
Unassigned
4
25
-
26
50
-
53
Gross
Weight 4
27
-
28
54
-
57
Tare
Weight
4
29
-
30
58
-
61
Net
Weight 4
31
-
32
62
-
65
Setpoint
1 4
33
-
34
66
-
69
Setpoint
2 4
35 - 36
70 - 73
Flow Rate (weight /second) 4
37
-
39
74
-
79
Unassigned
6
40
80
-
81
Status
Word
0
2 Scale 2
41
82
-
83
Status
Word
1 2
42
84
-
85
Status
Word
2 2
43
-
44
86
-
89
Unassigned
4
45
-
46
90
-
93
Gross
Weight 4
47
-
48
94
-
97
Tare
Weight
4
49 - 50
98 – 101 Net Weight
4
51 - 52
102 - 105
Setpoint 1
4
53 - 54
106 - 109
Setpoint 2
4
55 - 56
110 - 113
Flow Rate (weight /second) 4
57
-
59
114
-
119
Unassigned
6