Appendix III: SMA Protocol

A. STANDARD SCALE RESPONSE MESSAGE

Most of the host commands are responded to in the following message format. The only
host commands that do not are the:
D

iagnostic, ABout and INformation commands

<LF> <s> <r> <n> <m> <f> <xxxxxx.xxx> <uuu> <CR>

where:

<LF>

Start of response message

<s>

scale status

definition / example

‘Z’

Center of Zero <xxxxxx.xxx>= 0.000

‘O’

Over

Capacity

<xxxxxx.xxx>=

+weight

‘U’

Under

Capacity <xxxxxx.xxx>= -weight

‘E’

Zero Error (clears when condition clears)

‘I’

Initial-Zero Error (if used, this error is

maintained until zero condition is cleared)

‘T’

Tare Error (clears after being read)

<space>

None of the above conditions

Note: For ‘E’, ‘I’, ‘T’ error conditions
<xxxxxx.xxx>= ————— (center dashes)
and ‘Z’, ‘O’, ‘U’ are overridden.

<r>

range

(‘1’, ‘2’, ‘3’, etc.) always ‘1’ for single range

<n>

gross/net status

‘G’

Gross normal weight

‘T’

Tare weight (in response to ‘M’ command)

‘N’

Net normal weight

‘g’

gross weight in high-resolution

‘n’

net weight in high-resolution

<m>

motion status

‘M’

scale in Motion

<space>

scale not in Motion

<f>

future

reserved for future or custom use

<xxxxxx.xxx>

weight data this field is fixed at 10 characters

<uuu>

Unit of Measure

<CR>

End of response message