5.8.3. CONTROLNET

CONTROLNET

(

30924

)

is an open

ControlNetwork running in “real-time”, for high-
throughput applications.

– It uses a Control and Information Protocol

(CIP), combining the functionality of an I/O
Network and a Peer-to-Peer Network.

CONTROLNET

is based on the

Producer/Consumer Model

, permiting all

nodes on the network to simultaneously
access the same data from a single source.

– Maximum

of

99 nodes

, with no minimum

distance between nodes

– The ControlNet card uses BNC connectors.



SPECIAL NOTES

For signal redundancy, both connectors should be used.

– If not, use either Connector A or B.

Network Status LED A

and Module Status LED correspond to LED 1 and LED 2 in

the instance attributes of the Anybus Object.

– They are available in the application interface, but the LED placement on the

front does not conform to the standard Anybus CompactCom placement of
LED 1

and LED 2.