Method 1, continued – Fairbanks FB2550 DAT SERIES DRIVER ACCESS TERMINAL User Manual

Page 55

Advertising
background image

Section 3: Configuration Menu

2/2013

55

51303 Rev. 1

4.4.3. METHOD 1, CONTINUED

13. Enter the

SETTINGS

menu to configure

the settings as required.

14. Touch the data field to the right of the

Mode legend and a list of items will appear
from which a selection is made.



MODE

–

This field determines how the

data is transmitted.

OFF

–

COM port is disabled.

CONTINUOUS

–

The COM port

transmits the data string continuously per
every display update.

DEMAND

–

The data string is

transmitted upon receiving the
programmed poll character from a peripheral device.

AUTO

–

The data string is transmitted upon the printing of a transaction.

NETWORK

(CONTINUOUS)

-

The data string is transmitted continuously

per every display update through the network connection.

NETWORK (AUTO)

-

The data string is transmitted upon pressing print and

the printing of a transaction will transmit the transaction through the network
connection.


15. Touch the data field to the right of the

Baud legend and a list of items will appear
from which a selection is made.

16. Select the required

BAUD

rate from the

menu list.