Appendix vi: remote serial communication commands – Fairbanks FB2550 DAT SERIES DRIVER ACCESS TERMINAL User Manual
Page 156

2/2013
156
51303 Rev. 1
Appendix VI: Remote Serial Communication
Commands
COMMAND
DESCRIPTION
A
Auto Tare Active scale
G
Turn Traffic Light Green (Manual Mode only)
LA
Change Traffic Light to Automatic mode
LM
Change Traffic Light to Manual mode
R
Turn Traffic Light Red (Manual Mode only)
S#
Change Active Scale (where
#
= scale number)
Txxxxx
Set Tare on Active scale (where
xxxxx
= tare weight value required)
T#,xxxxx
Tare entry for a specific scale (where
#
= scale number, and where
xxxxx
= tare
weight value required)
U#
Toggle Units on a scale (where
x
= scale number)
u
Toggle All Scales Units
U
Toggle Units on Active scale
Z#
Zero one scale (where
#
= scale number)
z
Zero all scales
Z
Zero Active scale
P
Print Active scale
W
Demand request for a Weight output on the Active scale