Appendix II: Data Output
A. REMOTE
DISPLAY
OUTPUT
Data Format
<STX><4><0><SP/-><XXXXXX><ETX >
NOTES:
1. Characters denoted by
X
are characters 0-9.
2. Leading zeroes are suppressed.
3. Polarity indication for a positive value is a space (
SP
).
Negative values are not transmitted.
4.
Identifier code <4><0> = Gross weight
.
Transmission is Gross Only.
5. Transmission for the DEMAND Mode occurs when a carriage return
(CR) Hex
0D
is received.
B. CONFIGURE
OUTPUT
FAIRBANKS DATA FORMAT
<STX><A><B><C><GGGGGG><TTTTTT><CR>
NOTES:
1. Characters denoted by
G
and
T
are characters 0-9.
2. Leading zeroes are suppressed.
3. Gross Weight Data =
G
Tare Weight Data =
T
Status Code (Word) A
Bit #
X00
X0
X
X.X
X.XX
X.XXX
X.XXXX
X.XXXXX
0 0 1 0 1 0 1 0 1
1 0 0 1 1 0 0 1 1
2 0 0 0 0 1 1 1 1