Section 3: Configuration Menu

2/2013

53

51303 Rev. 1

4.4.3. METHOD 1, CONTINUED

7. Select the

LOAD

button.

– This selection will bring up a menu a five

(5) pre-configured outputs

.





8. When configuring an output data string, the

Fairbanks’ FB2550 DAT has seven (7)
commonly used pre-configured outputs.

9. Select the correct data string type.



Displayed below are the data string protocols.

*

FAIRBANKS

<STX><A><B><C><GGGGGG><TTTTTT><CR>

Toledo

<STX><A><B><C><GGGGGG><TTTTTT><CR>

Cardinal

<CR><P><WWWWWW><M><SP><U><SP><G><SP><SP><ETX>

Weightronix

< ><M><WWWWWW>< ><U><CR><LF>

Condec

<STX><P><WWWWWW><U><G><M><CR>

DT7000 Anybus

<STX><SW0><SW1><SW2><UD><GW><TW>NW><SP1><SP2><FR><UD><CRC><XCH

>

SMA Protocol

<LF> <S> <R> <N> <M> <F> <XXXXXX.XXX> <UUU> <CR>


*

See

Appendix II: Data Output

for further information.