Custom Monitor

In the custom monitor, a maximum of 30 devices and corresponding data types can be specified to monitor and control.

1.

Enter the device (type and number) in the Device Number.

"D" (data register) or "m" (internal relay) can be specified. Specify data device number in decimal, such as D2058 or
m0112.

2.

Select the monitor type to display the corresponding device in the desired format.

Data registers or internal relays values are shown in the format specified by the monitor type. See the data type for the
available data types.

3.

Click on a cell in Value column in which data register value is shown.

A dialog box to write a data is shown. The entered value is written to the Web server CPU module.