IDEC MicroSmart Pentra User Manual

Page 73

Advertising
background image

W

EB

S

ERVER

CPU M

ODULE

U

SER

S

M

ANUAL

FC9Y-B1278

5-13

5: F

UNCTION

A

REA

S

ETTINGS

Client Connection Status and Connected IP Address
The connection status of client connections with remote hosts can be confirmed with special internal relays M8215 to
M8217. When a connection with a remote host is established, the corresponding special internal relay is turned on.
When the connection is disconnected, the corresponding special internal relay is turned off. The IP addresses of the
remote hosts can be confirmed with special data registers D8394 to D8405.

Special Internal Relays

Special Data Registers

Sever Connection Status and Connected IP Address
The connection status of server connections with network client devices can be confirmed with special internal relays
M8220 to M8227. When a connection with a client device is established, the corresponding special internal relay is
turned on. When the connection is disconnected, the corresponding special internal relay is turned off. The IP addresses
of the client devices can be confirmed with special data registers D8362 to D8493.

Special Internal Relays

Special Data Registers

Device Address

Description

Details

M8215

Client Connection 1 Status

While a connection is established with a remote
host, the special internal relay will be on. When
no connection is established, it will be off.

M8216

Client Connection 2 Status

M8217

Client Connection 3 Status

Device Address

Description

Details

D8394-D8397

Client Connection 1
Connected IP Address

IP address is stored in the corresponding special
data registers. For example, when the IP address is
aaa.bbb.ccc.ddd, each value is stored as follows:
D8394=aaa, D8395=bbb, D8396=ccc, and
D8397=ddd.

D8398-D8401

Client Connection 2
Connected IP Address

D8402-D8405

Client Connection 3
Connected IP Address

Device Address

Description

Details

M8220

Server Connection 1 Status

While a connection is established with a client
device, the corresponding special internal relay
will be on. When no connection is established, it
will be off.

M8221

Server Connection 2 Status

M8222

Server Connection 3 Status

M8223

Server Connection 4 Status

M8224

Server Connection 5 Status

M8225

Server Connection 6 Status

M8226

Server Connection 7 Status

M8227

Server Connection 8 Status

Device Address

Description

Details

D8362-D8365

Server Connection 1 Connected IP Address

IP address is stored in the corresponding special
data registers. For example, when the IP address is
aaa.bbb.ccc.ddd, each value is stored as follows:
D8362=aaa, D8363=bbb, D8364=ccc, and
D8365=ddd.

D8366-D8369

Server Connection 2 Connected IP Address

D8370-D8373

Server Connection 3 Connected IP Address

D8374-D8377

Server Connection 4 Connected IP Address

D8378-D8381

Server Connection 5 Connected IP Address

D8382-D8385

Server Connection 6 Connected IP Address

D8386-D8389

Server Connection 7 Connected IP Address

D8390-D8393

Server Connection 8 Connected IP Address

Advertising