Communication Setup Procedure

This section describes the procedure to set up communication between a PC and the PLC, using an example. WindLDR is
used to configure the network settings of the Web server CPU module and monitor the status of the CPU module using
an Ethernet connection.

USB Connection

1.

Select Online from the WindLDR menu bar, then select Set Up.

The Communication Settings dialog box appears.

2.

Select USB and click

OK

button.

3.

Select Configuration from the WindLDR menu bar, and then click Network Settings.

4.

The Function Area Settings dialog box appears. Enter the IP address, subnet mask, and default gateway, then click OK
button.

5.

Select Online from the WindLDR menu bar, and then click Download.

Note: To communicate with the PLC using a USB connection, the USB driver must be installed on your PC. For the procedure to install
the driver, see “USB Driver Installation Procedure” on page A-3.