Simulate Operation

Before downloading the user program, you can simulate the operation on the WindLDR screen without connecting the
Web server CPU module.
From the WindLDR menu bar, select Online > Simulation. The Simulation screen appears.

To change an input status, place the mouse pointer on the input and right-click the mouse. In the pop-up menu, select
Set or Reset to set or reset the input.
To quit simulation, from the WindLDR menu bar, select Online > Simulation.

Download Program

You can download the user program from WindLDR running on a PC to the Web server CPU module.
From the WindLDR menu bar, select Online > Download. The Download Dialog appears, then click the OK button. The
user program is downloaded to the Web server CPU module.

Note: When downloading a user program, all values and
selections in the Function Area Settings are also
downloaded to the Web server CPU module.

Note: The Download Dialog is also shown by selecting
Home > Download.