b. IECEx Intrinsically Safe Type

Caution for IECEx Intrinsically safe type.

Note 1. FVX110 Fieldbus Segment Indicator with

optional code /SS25 are applicable for use

in hazardous locations:

• No. IECEx DEK 11.0004 X

• Applicable Standard:

IEC60079-0:2007, IEC60079-11:2006,

IEC60079-26:2006, IEC60079-27:2008

Note 2. Ratings

[Ex ia IIB/IIC T4 Ga]

• Type of Protection: II1G Ex ia IIB/IIC T4 Ga

• Ambient Temperature: –40* to 60ºC

* –15ºC when O-ring material is Fluoro-rubber.

• Degree of Protection of the Enclosure:

IP66 and IP67

• When combined with Trapezoidal output

characteristic FISCO model

IIC or IIB barrier

[Supply/Output circuit (terminals + and –)]

Ui = 17.5 V, Ii = 500 mA, Pi = 5.5 W,

Ci = 3.52 nF, Li = 0

• When combined with Linear characteristic

barrier

[Supply/Output circuit (terminals + and –)]

Ui = 24.0 V, Ii = 250 mA, Pi = 1.2 W,

Ci = 3.52 nF, Li = 0

[Ex ic IIC T4 Gc]

• Type of Protection: II3G Ex ic IIC T4 Gc

• Ambient Temperature: –40* to 60ºC

* –15ºC when O-ring material is Fluoro-rubber.

• Degree of Protection of the Enclosure:

IP66 and IP67

[Supply/Output circuit (terminals + and –)]

Ui = 32.0 V, Ci = 3.52 nF, Li = 0

Note 3. Installation

• In any safety barrier used output current

must be limited by a resistor 'R' such that

Io=Uo/R.

• The safety barrier must be IECEx certified.

• Input voltage of the safety barrier must be

less than 250 Vrms/Vdc.

• The instrument modification or parts

replacement by other than authorized

representative of Yokogawa Electric

Corporation and will void IECEx Intrinsically

safe certification.

Non-Hazardous Location

Hazardous Location

F0214.ai

Terminator

Safety Barrier

Field Instruments

Indicator

Field Instruments

+

+

+

Terminator

+

+

[Intrinsically safe apparatus level of protection “ia”]

F0215.ai