<13. General Specifications>

13-3

IM 01S01C01-01EN

13.4 Optional Specifications (For Explosion Protected type)

Item

Description

Code

Factory

Mutual (FM)

FM Explosionproof Approval *

1

Applicable Standard: FM3600, FM3615, FM3810, ANSI/NEMA 250

Explosionproof for Class I, Division 1, Groups B, C and D,

Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G, Enclosure Rating: NEMA Type 4X

Temperature class: T6, Amb. Temp.: –40 to 60°C (–40 to 140°F)

FF1

FM Intrinsically Safe and Nonincendive Approval *

1

Applicable Standard: FM3600, FM3610, FM3611, FM3810, ANSI/NEMA 250, ISA60079-27

Intrinsically Safe for Class I,II, & III, Division 1, Groups A,B,C,D,E,F & G, Entity, FISCO. /Class I, Zone 0,

AEx ia IIC,

Enclosure: "NEMA 4X", Temp. Class: T4, Amb. Temp.: –40 to 60°C (–40 to 140°F).

Intrinsically Apparatus Parameters :

[FISCO (IIC)] Ui=17.5 V, Ii=500 mA, Pi=5.5 W, Ci=1.76 nF, Li=0 µH

[FISCO (IIB)] Ui=17.5 V, Ii=500 mA, Pi=5.5 W, Ci=1.76 nF, Li=0 µH

[Entity] Ui=24 V, Ii=250 mA, Pi=1.2 W, Ci=1.76 nF, Li=0 µH

Nonincendive for Class I, Division 2, Groups A, B, C and D, NIFW, FNICO

Class I, Zone 2, Group IIC, NIFW, FNICO

Class II, Division 2, Groups F&G, and Class III, Division 1

Enclosure: "NEMA 4X", Temp. Class: T4, Amb. Temp.: –40 to 60°C (–40 to 140°F)

Nonincendive Apparatus Parameters : Vmax.=32 V, Ci=1.76 nF, Li=0 µH

FS15

CENELEC

ATEX

CENELEC ATEX (KEMA) Flameproof Approval *

1

Applicable Standard: EN 60079-0, EN 60079-1, EN 61241-0, EN 61241-1

Certificate: KEMA 10ATEX0157

II 2G, 2D Ex d IIC T6 Ex tD A21 IP6X T80 Degree of protection : IP66 and IP67

Amb. Temp. (Tamb) for gas-proof : T6; –50 to 75°C (–58 to 167°F)

Max. surface Temp. for dust-proof : T80°C (Tamb: –40 to 167°F)

KF25

CENELEC ATEX (DEKRA) Intrinsically safe Approval *

1

Certificate: DEKRA 11ATEX0022 X

Applicable standards: EN 60079-0, EN 60079-11, EN 60079-26, EN 60079-27, EN 61241-11

II 1G Ex ia IIB/IIC T4 Ga, II 1D Ex ia IIIC T80°C Da IP6X

Amb. Temp.: –40 to 60°C (–40 to 140°F)

Max. Surface Temp. for dust-proof: T80°C (Tamb.: –40 to 140°F)

Enclosure: IP66 and IP67

[FISCO (IIC)] Ui=17.5 V, Ii=500 mA, Pi=5.5 W, Ci=3.52 nF, Li=0 µH

[FISCO (IIB)] Ui=17.5 V, Ii=500 mA, Pi=5.5 W, Ci=3.52 nF, Li=0 µH

[Entity] Ui=24 V, Ii=250 mA, Pi=1.2 W, Ci=3.52 nF, Li=0 µH

KS25

Canadian

Standards

Association

(CSA)

CSA Explosionproof Approval *

1

Certificate: 2325751

Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.0.5, C22.2 No.25, C22.2 No.30, C22.2 No.94,

C22.2 No.213, C22.2 No.60079-0, C22.2 No.60079-1, C22.2 No.61010-1-04

Explosion-proof for Class I, Groups B, C and D.

Dustignition-proof for Class II/III, Groups E, F and G.

When installed in Division 2, "SEAL NOT REQUIRED" Enclosure: TYPE 4X, Temp. Class: T6

Ex d IIC T6 Enclosure: IP66 and IP67

Amb.Temp.: –50 to 75°C (–58 to 167°F)

CF1

CSA Intrinsically safe Approval *

1

Certificate: 2346277

Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.25, C22.2 No.94, C22.2 No.157, C22.2 No.213,

C22.2 No.61010-1-04

CAN/CSA E60079-0, CAN/CSA E60079-11, CAN/CSA E60079-15, IEC 60529

Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G,

Class III Division 4; Ex ia IIC T4

Amb. Temp.: –40 to 60°C (–40 to 140°F) Encl. Type 4X, IP66 and IP67

Entity Parameters for Intrinsically Safe:

Ui (Vmax)=24 V, Ii (Imax)=250 mA, Pi (Pmax)=1.2 W, Ci=1.76 nF, Li=0 µH or

Ui (Vmax)=17.5 V, Ii (Imax)=500 mA, Pi (Pmax)=5.5 W, Ci=1.76 nF, Li=0 µH

Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division 2, Groups F & G,

Class III Division 1; Ex nL IIC T4

Amb. Temp.: –40 to 60°C (–40 to 140°F) Encl. Type 4X, IP66 and IP67

Entity Parameters for Nonincendive: Ui=32 V, Ci=1.76 nF, Li=0 µH

CS15