5.3.1 Wiring Precautions

IMPORTANT

• Lay wiring as far as possible from electrical

noise sources such as large capacity

transformers, motors, and power supplies.

• Remove the electrical connection dust cap

before wiring.

• All threaded parts must be treated with

waterproofing sealant. (A non-hardening

silicone group sealant is recommended.)

• To prevent noise pickup, do not pass signal

and power cables through the same ducts.

• Explosion-protected instruments must

be wired in accordance with specific

requirements (and, in certain countries,

legal regulations) in order to preserve the

effectiveness of their explosion-protected

features.

• The terminal box cover is locked by an

Allen head bolt (a shrouding bolt) on ATEX

flameproof type indicators. When the

shrouding bolt is driven clockwise using

an Allen wrench, it goes in. The cover lock

can then be released and the cover can

be opened by hand. See subsection 10.2

“Disassembly and Reassembly” for details.

• Plug and seal an unused conduit connection.

5.3.2 Wiring Installation

(1) General-use Type and Intrinsically Safe

Type

With the cable wiring, use a metallic conduit or

waterproof glands.

• Apply a non-hardening sealant to the terminal

box connection port and to the threads on the

flexible metal conduit for waterproofing.

F0502.ai

Flexible metal conduit

Wiring metal

conduit

Tee

Drain plug

Apply a non-hardening

sealant to the threads for

waterproofing.

Flameproof packing adapter

Figure 5.2

Typical Wiring Using Flexible Metal

Conduit

(2) Flameproof Type
Wire cables through a flameproof packing adapter,

or use a flameproof metal conduit.
■ Wiring cable through flameproof packing

adapter.

• Apply a non-hardening sealant to the terminal

box connection port and to the threads on the

flameproof packing adapter for waterproofing.

F0503.ai

Flameproof packing adapter

Flexible metal conduit

Wiring metal

conduit

Tee

Drain plug

Apply a non-hardening

sealant to the threads for

waterproofing.

Figure 5.3

Typical Cable Wiring Using Flameproof

Packing Adapter