5 optional specifications, Optional specifications -4 – Yokogawa FVX110 User Manual

Page 88

Advertising
background image

<13. General Specifications>

13-4

IM 01S01C01-01EN

Item

Description

Code

IECEx

Scheme

IECEx Flameproof Approval *

1

Applicable Standard: IEC 60079-0, IEC60079-1

Certificate: IECEx KEM 10.0071

Flameproof for Zone 1, Ex d IIC T6 Enclosure: IP66 and IP67

Amb.Temp.: –50 to 75°C (–58 to 167°F)

SF25

IECEx Intrinsically safe and type n Approval *

1

No. IECEx DEK 11.0004 X

Applicable Standard: IEC 60079-0, IEC 60079-11, IEC 60079-26, IEC 60079-27,

Ex ia IIB/IIC T4, Ga Ex ic IIC T4 GC

Ambient Temperature: –40 to 60°C

Enclosure: IP66 and IP67

Intrinsically safe ratings (Ex ia IIB/IIC T4)

[Entity] Ui=24 V, Ii=250 mA, Pi=1.2 W, Ci=3.52 nF, Li=0 µH

[FISCO IIC] Ui=17.5 V, Ii=500 mA, Pi=5.5 W, Ci=3.52 nF, Li=0 µH

[FISCO IIB] Ui=17.5 V, Ii=500 mA, Pi=5.5 W, Ci=3.52 nF, Li=0 µH

Intrinsically safe ratings (Ex ic IIC T4): Ui=32 V, Ci=3.52 nF, Li=0 µH

SS25

*1: Applicable for Electrical connection code 2, 4, 7, 9, C and D.

13.5 Optional Specifications

Item

Description

Optional code

Painting

Color change

Amplifier cover only

*1

P

Amplifier cover and terminal cover, Munsell 7.5 R4/14

PR

Coating change

Anti-corrosion coating

*1*2

X2

316 SST exterior parts

316 SST name plate, tag plate and screw

*3

HC

Lightning protector

Power supply voltage: 10.5 to 32 V DC (10.5 to 30 V DC for intrinsically safe

type, 9 to 32 V DC for Fieldbus communication type)

Allowable current: Max. 6000A (1x40μs), Repeating 1000A (1x40μs) 100times

A

Wired tag plate

304 SST tag plate wired onto indicator (316 SST when /HC is specified)

N4

*1: Not applicable for amplifier housing code 2

*2: Not applicable with color change option

*3: 316 SST or 316L SST. The specification is included in amplifier housing code 2.