WIRING

Wiring Safety

At installation, be sure to comply with the following requirements:

Disconnect power to the unit before attempting any connection or service to the unit

Do not bundle or route signal lines with power lines

Keep all lines as short as possible

Use twisted pair shielded wire for all output wiring

Observe all applicable, local electrical codes

Opening the M2000 Cover

The M2000 amplifier's design lets you open the cover without completely removing it

Cover is attached with display ribbon cable

To open the cover you will need a blade screwdriver
Follow these steps:

1 Disconnect power to the unit
2 Completely remove the two screws from either the left or the right side of

the amplifier

3 Loosen each of the remaining screws so that the round head of the screw clears the top edge of the cover

4 Lift and pivot the cover into the open position