Badger Meter M-Series M2000 User Manual

Page 38

Advertising
background image

Inputs/Outputs

Digital Output

Select Function
[1: Forward Pulse]

[2: Reverse Pulse]

[3: Frequency Pulse]

[4: Error Alarm]

S

Digital Output lets you configure the functional operation of the associated

output The following operations are supported:

• Reverse Pulse – Generates pulses during reverse flow conditions
• Forward Pulse – Generates pulses during forward flow conditions
• Frequency Output – Generates pulses correlated to the absolute value of

the flow rate

• Preset Output – Provides indication when preset batch amount has been

realized

• Flow Set Point – Provides indication when flow rate exceeds thresholds

defined by flow set points

• 24V DC Supply – Provides constant 24 volts on output (forces output type

to normally open)

• Error Alarm – Provides indication when meter has error condition Error

conditions include, empty pipe error, full scale flow error, and detector

error

• Flow Direction – Provides indication on current flow direction

(Inactive = Reverse or No Flow, Active = Forward)

• Empty Pipe Alarm – Provides indication when pipe is empty
• ADE – Provides meter information in digital format See "ADE Interface" on

page 52

To change the Function Select, follow these steps from the Inputs/Outputs main

menu:

1 Select Digital Output 1, 2, 3 or 4 and press [E] to open the Digital Output

menu

2 From the Digital Output menu choose Select Function, and press [E] to

open the Select Function display

3 Select the desired function
4 Press [E] to save and return to the Digital Output menu

Flow Simulation

[Off]

S

Flow Simulation provides output simulation based on a percentage of the full scale flow Simulation

will not accumulate the totalizers The range of simulation includes –100% to 100% of the full scale

flow
The Flow Simulation Parameter lets you set the range of simulation in 10% increments
To change the Flow Simulation, follow these steps from the Inputs/Outputs menu:

1 Select Flow Simulation to view the Flow Simulation display
2 Click [+] to increment the percentage by 10, or click [–] to decrement the percentage by 10
3 Press [E] to save the displayed setting and return to the Inputs/Outputs menu

M-Series® M2000 Electromagnetic Flow Meter

Page 38

August 2012