Badger Meter M-Series M2000 User Manual

Page 49

Advertising
background image

Info/Help

Error Counts

[0]

U

Description

This menu provides a diagnostic view of the meter’s performance Below are several

system diagnostic counters and their definitions Use discretion when interpreting

these counters These values could be altered during system setup or when using

the verification device We suggest that you reset these counters before you start

monitoring your system and look for conditions possibly affecting performance

Detector

The number of times an invalid detector condition has been observed

Empty Pipe

The number of times an empty pipe condition has been observed by the meter

Full Scale

The number of times the flow has exceeded the full scale flow setting

Totalizer

The number of times the totalizers have exceeded limits of the meter

Pulse Sync.

The number of times the pulse outputs have fallen out of synchronization

ADC Interrupt

The number of times an analog input measurement has been missed

ADC Range

The number of times the analog input measurement range has been exceeded

System Error

A diagnostic system message indicating the reason for a system reset

System Resets

The number of times the meter has been reset

System Reset ID Diagnostic information about a system reset as a result of expired internal timers

Token Errors

Indicates the number of parameter copies from a memory token that failed to be copied

to the meter

Installation & Operation Manual

Page 49