Badger Meter M-Series M2000 User Manual

Page 42

Advertising
background image

Communication: Diagnostics

Port Counters
[0]

S

Port counters are used for diagnostics when configured for MODBUS RTU These counters are only cleared

on power up

Counter

Description

Pkts Processed Number of packets processed by meter
Broadcast Pkts Number of broadcast packets (address = 0) processed by meter
CRC Errors

Number of received packets with CRC error; packet is discarded

Pkts Rcvd

Number of packets received with an address of the configured port address

Pkts Sent

Number of packets transmitted in response to a received packet

Parity Errors

Number of characters with parity errors (i.e., received character has a mismatch

between the number of 1s and its parity bit); packet is discarded

Framing Errors Number of characters with framing errors (i.e. missing stop bit is not found –

indicates that synchronization with the start bit has been lost and that the character

is improperly framed); packet is discarded

Overrun Errors Number of characters received that were not processed due to degradation of

system performance

Break Detects

Number of detections that transmission line is locked (i.e., receive line is low for

10-bit transmissions following a missing stop bit)

M-Series® M2000 Electromagnetic Flow Meter