Communication: Port Settings

Parity
[Even]

S

The following Parities are supported

• Even
• Odd
• None

To change the parity, follow these steps from the Port A Settings menu:

1 Select Parity to view the Parity display
2 Select one of the following: None, Even or Odd
3 Press [E] to save the option and to return to the Port A Settings menu

Stop Bits
[1 Stop Bit]

S

The Stop Bits parameter configures the port stop bits The following stop bits are supported:

• 1 Stop Bit
• 2 Stop Bits

To change the stop bits, follow these steps from the Port A Settings menu:

1 Select Stop Bits to view the Stop Bits display
2 Select one of the following: 1 Stop Bit, or 2 Stop Bits
3 Press [E] to save the option and to return to the Port A Settings menu

Communication: Port B

Port Address
[1]

S

An additional communication port, known as Port B, is used to offer enhanced communications with the

meter This port is located on the 11-pin terminal of the PCB Enhanced protocols like Hart, Profibus DP

or Modbus RTU over RS485 are available In addition, this communication port has similar configurable

properties as port A Refer to the following IOMs for additional information regarding the enhanced

communication capabilities of the M2000

• See IOM-191-XX-EN for details on HART® communication protocol

• See IOM-192-XX-EN for details on PROFIBUS DP communication protocol

• See IOM-193-XX-EN for details on MODBUS RTU communication protocol