Advanced Features

Unit Multiplier

[Off]

U

The Unit Multiplier establishes the number of units of measure that have to accumulate before the

display totalizers are updated This is also known as setting the number of “dead” zeroes in the display

totalizer For example:

Unit Multiplier less than 1

Unit Multiplier Example
OFF

0.00000 USG

0.00012 USG

0.00123 USG

0.01234 USG

0.12345 USG

0.0001

0.0000 USG

0.0001 USG

0.0012 USG

0.0123 USG

0.1234 USG

0.001

0.000 USG

0.000 USG

0.001 USG

0.012 USG

0.123 USG

0.01

0.00 USG

0.00 USG

0.00 USG

0.01 USG

0.12 USG

0.1

0.0 USG

0.0 USG

0.0 USG

0.0 USG

0.1 USG

Unit Multiplier greater than or equal to 1

Unit Multiplier Example
OFF

0.00000 USG

1.23456 USG

12.34567 USG

123.4567 USG

1234.456 USG

1

0 USG

1 USG

12 USG

123 USG

1234 USG

10

0 USG

0 USG

10 USG

120 USG

1230 USG

100

0 USG

0 USG

0 USG

100 USG

1200 USG

1000

0 USG

0 USG

0 USG

0 USG

1000 USG

To change the Unit Multiplier, follow these steps from the Advanced menu:

1 Select Unit Multiplier to view the Unit Multiplier display
2 Select the desired unit multiplier
3 Press [E] to save the option and to return to the Advanced menu

Backlight Control

[Timed Off]

U

You can set the meter's backlight to: Always On, Always Off and Timed Off
When set to Timed Off, the backlight will automatically turn off after one minute of inactivity

(no buttons pressed) Pressing any button will turn the backlight on, but will not immediately

navigate the menu
To change the backlight control, follow these steps from the Advanced menu:

1 Select Backlight Control to view the Backlight Control display
2 Select the desired option
3 Press [E] to save the option and to return to the Advanced menu

Token Copy

Configuration

Refer to IOM-194-XX-EN for details on using the

Token Copy features

Store to Token
Restore from Token