Changing a diskset’s sparepool assignment, Changing a diskset’s sparepool assignment 5-26 – HP NetRAID-4M Controller User Manual

Page 104

Advertising
background image

5-26

Command Line Interface User’s Guide

Disks Attached OS Managed Label Shared Spare

------ -------- ---------- ---------- ------ -----

3 NO NO Mercury YES NO

Changing a Diskset’s Sparepool Assignment

Changing a diskset’s sparepool assignment either assigns a diskset
to a sparepool or unassigns a diskset from a sparepool. To change a
diskset’s sparepool assignment, the diskset must be owned and
attached by either the controlling or peer partner. You use the

disk_set changespare pool

command to change a diskset’s

sparepool assignment.

Before changing a diskset’s sparepool assignment, use the

disk_set list

command to display information about your

disksets, as in the following example. In the example, the Spare
column indicates NO, which means that the diskset is not assigned
as a spare. Note that the example alters the

disk_set list

output

so that the data can fit on the page.

HPN0> disk_set list

Executing: disk_set list

Diskset ID Creator ID Owner

------------------- ------------------ ------------------

0x01be868c1d74a640 0xfafaf001007a1c00 \\.\HPN0

Disks Attached OS Managed Label Shared Spare

------ -------- ---------- ---------- ------ -----

3 Yes NO Mercury YES NO

To change a diskset’s sparepool assignment, use the

disk_set

changespare pool

command, as in the following example. In the

example, the command changes the sparepool assignment of the
diskset whose diskset ID is 0x01be868c1d74a640 and whose creator
ID is 0xfafaf001007a1c00 to spare.

HPN0>disk_set changesparepool 0x01be868c1d74a640

0xfafaf001007a1c00 spare

Executing: disk_set changelabel 125,685,775,960,680,000

-361,712,932,956,267,520 "nonspare"

Advertising