Managing flash eprom components, Managing flash eprom components 3-18 – HP NetRAID-4M Controller User Manual

Page 42

Advertising
background image

3-18

Command Line Interface User’s Guide

Caution:

The controller deletes any data on the replacement

disk when automatic spare is enabled and you remove the
failed disk and insert the replacement disk in the failed
disk’s slot.

Note:

The automatic spare feature works only with disks

that reside in a SAF-TE enclosure management device.

The CLI allows you to do the following:

Display a controller’s automatic spare status

Enable automatic spare

To display a controller’s automatic spare status, use the

controller show automatic_spare

command, as in the

following example. In the example, the automatic spare feature is
indicated as DISABLED.

HPN0> controller show automatic_

spare

Executing: controller show automatic_

spare

Automatic

spare

DISABLED

To enable automatic spare, use the

controller set

automatic_spare

command with the

/

spare

switch, as in the

following example:

HPN0> controller set automatic_spare /spare_enabled=TRUE

Executing: controller set automatic_spare /spare_enabled=TRUE

After running the

controller set automatic_spare

command, use the

controller show automatic_spare

command again to verify that automatic spare has been enabled.
You can now replace a failed disk with a replacement disk, if
necessary.

Managing Flash EPROM Components

The CLI allows you to update the flash EPROM components of one
or more controllers. It can also be used to compare a controller’s
current flash contents to the flash images in a specified pair of user

!