Rescanning a controller, Pausing and resuming controller i/o – HP NetRAID-4M Controller User Manual

Page 39

Advertising
background image

3-15

Working with Controllers

Rescanning a Controller

The controller rescan operation scans the controller’s channels and
verifies the presence of currently connected devices and newly
connected devices. If any disk partition structures have changed,
rescanning updates those changes in the controller memory’s
container and partition lists. If you add devices to the controller, the
rescan enables the controller to use those devices.

The CLI allows you to do the following:

Display a list of channels on a controller

Rescan the channels connecting the controller and disks

To display a list of channels on a controller, use the

controller

show

channels command, as in the following example. In the

example, the Ch# column indicates channels 0 and 1 are present on
the controller.

HPN0> controller show channels

Executing: controller show channels

Ch# Host ID Targets Type Max Usage

--- ------- ------- --------- ---------

0 7 15 NoInfo NoInfo

1 7 15 NoInfo NoInfo

To rescan the controller, use the

controller rescan

command,

as in the following example:

HPN0> controller rescan

Executing: controller rescan

If you add a device to the controller, the

controller rescan

command verifies that the new device has been added. Use the

disk list

command to make sure the new device was recognized.

See Displaying the SCSI Device ID on page 4-2 for more information
on using the

disk list

command to display the SCSI device IDs.

Pausing and Resuming Controller I/O

I/O on a controller may need to be paused so that you can make
changes to attached devices without rebooting. For example you
may need to change SCSI channel assignments or swap disk drives.

Advertising