Buhler 535 User Manual

Page 193

Advertising
background image

4-60

435/485/535

F4-93

Operation 83

Change the Ether Canister

The cold start solenoid is mounted on the left side of
rear hood support .

Remove the protective yellow cap () or unscrew the
empty ether canister anti-clockwise from the top of
the solenoid valve (2), making sure that the gasket
remains in place . Lubricate the gasket with a light film
of clean oil .

Remove the protective cap from the new ether
canister .

Lower the ether canister (3) into the top of the solenoid
valve (2) and screw it in clockwise .

Tighten the ether canister hand tight only .

Once the ether canister is screwed into the solenoid
valve, secure the canister firmly by attaching the
clamp (4) around the canister . Tighten the clamp .

NOTE: The ether bottle is not shipped as standard

equipment from the factory and should be sourced

locally.

CAUTION:

STARTING

FLUID

IS

HIGHLY

FLAMMABLE. DO NOT USE NEAR FIRE, SPARKS,

OR FLAMES. BE SURE ALL OPERATORS READ THE

CAUTIONARY INFORMATION ON THE CANISTER.
CAUTION: THE ETHYL ETHER USED AS COLD

START FLUID IS EXTREMELY FLAMMABLE, TOXIC,

AND FATAL IF SWALLOWED. AVOID CONTACT WITH

EYES OR SKIN. AVOID BREATHING THE FUMES.
IF SWALLOWED, DO NOT INDUCE VOMITING. CALL

DOCTOR IMMEDIATELY.
IF COLD START FLUID ENTERS EYES OR FUMES

IRRITATE EYES, WASH EYES WITH LARGE

QUANTITIES OF CLEAN WATER FOR 15 MINUTES.

CONTACT A DOCTOR, PREFERABLY AN EYE

SPECIALIST, IMMEDIATELY.

1

F4-94

2

2

3

4

Section 4 - Lubrication & Maintenance

As Required

Advertising
This manual is related to the following products:

485, 435