Electrical system – Buhler 535 User Manual

Page 204

Advertising
background image

435/485/535

5-9

Problem

Tractor runs for a short

time and shuts off

Electrical system high/

low voltage

Batteries will not charge

Correction

Check audio and visual indicators for
cause of shutdown. Contact Buhler
Versatile dealer.

Contact Buhler Versatile dealer.

Clean and tighten connections.

Contact Buhler Versatile dealer.

Check each battery open circuit
voltage for . volts minimum.
Check electrolyte level and specific
gravity.

Check alternator belt tension.
Replace belt if required.

Clean and tighten connections.

Check each battery open circuit
voltage for . volts minimum.
Check electrolyte level and specific
gravity.

Check alternator belt tension.
Replace belt if required.

Possible Cause

Automatic shutdown mode activated.

Partially restricted fuel line.

Loose or corroded terminal
connections.

Shorted out electrical system.

Sulfated batteries.

Loose or worn belt.

Loose or corroded terminal
connections.

One or more batteries defective or
sulfated.


Loose or worn belt.

Electrical System