3 lsi system calibration, Lsi system calibration – JLG 4013PS Service Manual User Manual

Page 180

Advertising
background image

Electrical System

9-40

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

Note: Follow all adhesive manufacturer’s
recommendations including storage life.

5. Fit the sensor, ensuring the lead exits in the corner

direction. Secure with two bolts - Socket HD
Capscrew M10x35x1.5, Grade 12.9.

Note: It is important to prevent distortion of the sensor
element, therefore tighten each bolt finger tight.
Alternately tighten each bolt to 35 Nm (26 lb-ft) and
finally to 70-80 Nm (52-59 lb-ft).

6. Permanently mark position of bolt head and sensor

body.

7. Leave the machine undisturbed for a minimum of 6

hours before moving.

8. Plug the electrical connector into the sensor

assembly.

9. Properly connect the battery.

10. Close and secure the engine cover.

11. Remove the Do Not Operate Tag from the ignition

key switch and the steering wheel.

12. Calibrate the LSI system, refer to Section 9.16.3,

“LSI System Calibration.”

9.16.3

LSI System Calibration

a. Standard Calibration

To calibrate the LSI, certain conditions must be met:

The sensor must be installed according to Section

9.15.2, “LSI Sensor.”

The machine control system must be powered on for

at least 10 minutes before calibration.

The operator must remain in the cab.

The calibration shall be conducted with the standard

carriage and forks attached and weights as
necessary (a range of 60 - 80% of maximum weight
capacity.

The machine must be on a level surface with the

wheels steered straight and park brake off, with
straight driving over a distance of at least 2 m (6.5 ft)
being the last movement before entering a
calibration point).

While utilizing the LSI override button, 10 times lift

and lower the boom stopping suddenly to induce the
rear axle to bounce.

Position the rear tires centrally on the scales.

The calibration must be completed within 30 minutes

after starting procedure.

Calibration Procedure:

1. Start and position the machine to perform the

calibration procedure.

2. Remove the standard carriage, fork and weight

assembly.

3. Fully retract the boom and if equipped, lower the

outriggers. Shut the machine OFF.

4. With ignition key in OFF position, press and hold

SYSTEM CHECK button on LSI display and turn
ignition key to engine START position. Release the
ignition key when engine start is achieved, but
continue to hold SYSTEM CHECK button on LSI
display until the orange LED on LSI display goes out
and buzzer sounds (approximately 3 seconds).
Release SYSTEM CHECK button.

5. The LEDs will perform a rolling sequence. When

only the third green LED illuminates, press the
SYSTEM CHECK button.

6. The first green LED then illuminates. With no

attachment, outriggers down and boom retracted, lift
boom to maximum boom angle.

7. Press the SYSTEM CHECK button on the LSI

display and release. The first 3 green LEDs will
illuminate. The third then second green LEDs will go
out as the calibration point is recorded.

8. The first green LED goes out and buzzer sounds

then the red LED illuminates.

9. Lower boom until level. If equipped, fully raise

outriggers. Pressing the LMI Override button may be
required to lower the boom.

10. Attach the previously removed standard carriage,

forks and weight.

11. Slowly extend the boom until the rear axle weight in

the following table is achieved.

Advertising