SECTION 3 - CHASSIS & TURNTABLE

3-50

– JLG Lift –

3121180

Disassembly

NOTE: Removal of endcap voids warranty.

During assembly, coat all moving parts with a film of
clean hydraulic oil. This ensures parts are lubri-
cated during start-up.

Replace all O-Rings and gaskets. Lightly lubricate
O-rings with clean petroleum jelly prior to assembly.

1. Using a 11/16" wrench, remove plug (1) and (2).
2. Using a 5/8" hex wrench, remove plug (3).
3. Remove O-rings (4, 5, and 6).
4. Using pliers, remove centering springs (7, 8, and 9).
5. Remove spring retaining washers (10 and 11).
6. Remove shift spool (12).
7. Remove orifice poppet (13).

8. Remove all fittings from unit. Discard O-rings.
9. Using an 11/16" hex wrench, loosen speed sensor

lock nut (14) if equipped and remove speed sensor.
Units without speed sensor have an O-ring plug (15)
installed in that location; remove it with a

1/4"

inch

internal hex wrench.

10. Using a 1/4" internal hex wrench, remove control line

plugs (16, 17). Discard O-rings. Using a 3 mm hex
wrench, remove cavity plug (18) (if equipped with
two-line control), from X2 cavity.

11. Using a 5/16" internal hex wrench, remove drain

plugs (19, 20). Discard O-rings.

12. If equipped with axial ports, use a 9/16" an internal

hex wrench and remove work port plugs (21). Discard
O-rings.

5

3

7

13

2

6

9

11

1

4

8

10

12

1. Plug
2. Plug
3. Plug
4. O-ring

5. O-ring
6. O-ring
7. Spring
8. Spring

9. Spring
10. Washer
11. Washer

12. Shift Spool
13. Orifice Poppet

Figure 3-27. Loop Flushing Spool

15

20

16

16

19

17

18

21

14

14. Lock Nut
15. O-ring Plug
16. Control Line Plug
17. Control Line Plug

18. Cavity Plug
19. Drain Plug
20. Drain Plug
21. Work Port Plug

Figure 3-28. Plugs, Fittings, and Speed Sensor