Flash code 8/3 indicates problems with the Basket Leveling system.

10

BASKET LEVELING CRACKPOINT UP
NOT CALIBRATED

Only occurs on machines with electronic leveling systems. Indicates that the
basket up valve crackpoint has not been calibrated

BASKET LEVELING CRACKPOINT
DOWN NOT CALIBRATED

Only occurs on machines with electronic leveling systems. Indicates that the
basket down valve crackpoint has not been calibrated

BASKET LEVELING SENSOR 1 NOT
ZERO CALIBRATED

Only occurs on machines with electronic leveling systems. Indicates that the
primary basket leveling tilt sensor has not been calibrated.

BASKET LEVELING SENSOR 1 ZERO
OUT OF RANGE

Only occurs on machines with electronic leveling systems. Indicates that the
primary basket leveling tilt sensor zero is outside of the allowable range

BASKET LEVELING SENSOR 1
SHORT TO BATTERY

Only occurs on machines with electronic leveling systems. Indicates that the
primary basket leveling tilt sensor is shorted to battery. An EMS cycle is
required.

BASKET LEVELING SENSOR 1
SHORT TO GROUND OR OPEN CIR-
CUIT

Only occurs on machines with electronic leveling systems. Indicates that the
primary basket leveling tilt sensor is either shorted to ground or is not con-
nected. An EMS cycle is required.

BASKET LEVELING SENSOR 2 NOT
ZERO CALIBRATED

Only occurs on machines with electronic leveling systems. Indicates that the
secondary basket leveling tilt sensor is not zero calibrated.

BASKET LEVELING SENSOR 2 ZERO
OUT OF RANGE

Only occurs on machines with electronic leveling systems. Indicates that the
secondary basket leveling system tilt sensor zero is outside the allowable
range.

BASKET LEVELING SENSOR 2
SHORT TO BATTERY

Only occurs on machines with electronic leveling systems. Indicates that the
secondary basket leveling tilt sensor is shorted to battery. An EMS cycle is
required.

BASKET LEVELING SENSOR 2
SHORT TO GROUND OR OPEN CIR-
CUIT

Only occurs on machines with electronic leveling systems. Indicates that the
secondary basket leveling tilt sensor is either shorted to ground or not con-
nected. An EMS cycle is required.

BASKET LEVELING TILT REFERENCE
1 OUT OF RANGE

Only occurs on machines with electronic leveling systems. Indicates that the
reference voltage for the primary basket leveling tilt sensor is outside the
expected range (4.9 to 5.1 volts). An EMS cycle is required.

BASKET LEVELING TILT REFERENCE
2 OUT OF RANGE

Only occurs on machines with electronic leveling systems. Indicates that the
reference voltage for the secondary basket leveling tilt sensor is outside the
expected range. (4.9 to 5.1 volts). An EMS cycle is required.

BASKET LEVELING TILT SENSOR
DIFFERENCE TOO GREAT

Only occurs on machines with electronic leveling systems. Indicates that the
basket leveling tilt readings both appear to be good but their measurements do
not agree within a specified adjustable tolerance. An EMS cycle is required.

BASKET LEVELING SYSTEM TIME-
OUT

Only occurs on machines with electronic leveling systems. Indicates that the
basket was not able to maintain the desired level within an adjustable range for
and adjustable time

BASKET LEVELING OVERRIDE ON

User has forced basket leveling on through Access Level 0.

BASKET LEVELING OVERRIDE OFF

User has forced basket leveling off through Access Level 0.

BASKET LEVELING TILT SENSOR 1
COMMUNICATIONS LOST

Communications have been lost with a serial leveling sensor. Only on 1200S
and 1350S models. An EMS cycle is required.

BASKET LEVELING TILT SENSOR 2
COMMUNICATIONS LOST

Communications have been lost with a serial leveling sensor. Only on 1200S
and 1350S models. An EMS cycle is required.

Table 6-8. Help Fault Codes, Displayed Faults, and Descriptions - S/N 0300066949 & S/N 1300000001 to Present

Fault Flash

Code

Communicated (Displayed on

Analyzer) Fault

Description

Priority