Current Measurement

• Set up meter for expected current range.
• Connect meter leads to correct jacks for current

range selected.

• If meter is not auto ranging, set it to correct range

(See multi meter’s operation manual).

• Use firm contact with meter leads.

7.2 APPLYING SILICONE DIELECTRIC

COMPOUND TO ELECTRICAL
CONNECTIONS

NOTE: Do NOT apply dielectric grease to the following con-

nections:

• Main Boom Rotary sensor connections (on Celesco

Sensor).

• LSS Modules connections,
• Deutz EMR 2 ECM connection.

Silicone Dielectric Compound must be used on all electri-
cal connections except those listed above for the follow-
ing reasons:

• To prevent oxidation at mechanical joint between male

and female pins.

• To prevent electrical malfunction caused by low level

conductivity between pins when wet.

Use the following procedure to apply Silicone Dielectric
Compound to the electrical connectors. This procedure
applies to all plug connections not enclosed in a box. Sili-
cone grease should not be applied to connectors with
external seals.

1. To prevent oxidation, silicone grease must be

packed completely around male and female pins on
inside of connector before assembly. This is most
easily achieved using a syringe.

NOTE: Over a period of time, oxidation increases electrical

resistance at the connection, causing circuit failure.

2. To prevent shorting, silicone grease must be packed

around each wire where they enter the connector
housing. Also, silicone grease must be applied at
the joint where male and female connectors come
together. Any other joints (around strain reliefs, etc.)
where water could enter, connector should also be
sealed.

NOTE: This condition is especially common when machines

are pressure washed since washing solution is much
more conductive than water.

3. Anderson connectors for battery boxes and battery

chargers should have silicone grease applied to
contacts only.

NOTE: Curing-type sealants can also be used to prevent

shorting and are less messy, but make future pin
removal more difficult.

Figure 7-4. Current Measurement (DC)