5 function speeds, Machine orientation when doing speed tests, Test notes – JLG 450A_AJ Series II Service Manual User Manual

Page 19: 6 torque requirements, Function speeds -3, Torque requirements -3, Function speeds (in seconds) -3, Torque specification -3

Advertising
background image

SECTION 1 - SPECIFICATIONS

3121259

– JLG Lift –

1-3

1.5 FUNCTION SPEEDS

Machine Orientation When Doing Speed
Tests

Lift: Boom retracted. Telescope retracted. Lift up, record
time, Lift down, record time.

Swing: Boom at full elevation. Telescope retracted. Swing
turntable to end stop. Swing opposite direction, record
time. Swing opposite direction, record time.

Telescope: Boom at full elevation; Telescope retracted;
Telescope out, record time. Telescope In, record time.

Drive: Test to be done on a smooth level surface. Set
Drive Select Switch to 2WD High Engine. Start approxi-
mately 25 ft (7.62 m) from starting point so unit is at maxi-
mum speed when starting test. Record results for a 200 ft.
(60.96 m) course. Drive forward, record time. Drive
reverse, record time.

Drive (Above Horizontal): Test should be done on a
smooth level surface. Set Drive Select Switch to 2WD High
Engine. Select Platform Speed Knob out of creep speed.
This verifies switches are working when boom is above
horizontal. Results should be recorded for a 50 ft course.
Drive forward, record time. Drive reverse, record time.

Platform Rotate: Platform level and completely rotated
one direction. Rotate opposite direction, record time.
Rotate other direction, record time.

Articulating Jib: Platform level and centered with boom.
Start with Jib down. Jib up, record time. Jib down, record
time.

Lower Lift: Upper Boom horizontal. Telescoped In. Lower
Lift up, record time. Lower lift down, record time.

Test Notes

1. Start stop watch with function, not with controller or

switch.

2. Drive test results reflect 12x16.5 tires.

3. All speed tests are run from platform. These speeds

do not reflect ground control operation.

4. Platform speed knob control must be at full speed

(turned clockwise completely).

5. Test with oil temperature above 100° F (38° C). Func-

tion speeds vary if hydraulic oil is cold and thick.

6. Some flow control functions may not work with

speed knob clicked into creep position.

1.6 TORQUE REQUIREMENTS

Table 1-12. Function Speeds (In Seconds)

Function

450A

450AJ

Main Lift Up

24-28

24-28

Main Lift Down

20-24

20-24

Swing Right & Left*

70-90

70-90

Telescope Out

18-22

16-20

Telescope In

12-16

9-14

Platform Rotate Right & Left**

25-32

25-32

Jib Up

N/A

21-31

Jib Down

N/A

19-25

Lower Lift Up

30-38

30-38

Lower Lift Down

22-28

22-28

Drive (2WD High Engine)

38-41

(3.5 MPH)

38-41

(3.5 MPH)

Drive (4WD High Engine)

29-31

(4.5 MPH)

29-31

(4.5 MPH)

Drive above Horizontal
(50 ft.)

46-68

(0.75 - 0.50

MPH)

46-68

(0.75 - 0.50

MPH)

*Max 10% Difference Between Left & Right
**Max 15% Difference Between Left & Right

Table 1-13. Torque Specification

Description

Torque Value

Interval Hours

Wheel Lugs

170 ft. lb.

(230 Nm)

150

Semi-Track
Wheel Lugs

90 ft. lb.

(122 Nm)

150

Swing Bearing
(Loctite)

190 ft. lb.

(

257 Nm)

50/600*

Starter Solenoid
Contacts
Coil

95 in. lbs. (9.5 Nm)

40 in. lbs. (4 Nm)

As required

Drive Hub to Axle

240 ft. lb.

(325 Nm)

As required

Drive Motor to Axle

120 ft. lb.

(163 Nm)

As required

*Check swing bearing bolts for security after first 50 hours of operation
and every 600 hours thereafter.

Advertising