6 machine setup, Machine setup -7 – JLG 450A_AJ Series II Service Manual User Manual

Page 343

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121180

– JLG Lift –

6-7

6.5 ADJUSTING PARAMETERS USING THE

HAND HELD ANALYZER

Once you have gained access to level 1, and a personality
item is selected, press UP or DOWN arrow keys to adjust
its value, for example:

PERSONALITIES:
DRIVE ACCEL 1.0s

There is a minimum and maximum value for efficient
operation. Value will not increase if UP arrow is pressed at
maximum value and will not decrease if DOWN arrow is
pressed at minimum value for any particular personality. If
value does not change when pressing up and down
arrows, make sure you are at access level 1.

6.6 MACHINE SETUP

When a machine digit item is selected, press UP or DOWN
arrow keys to adjust its value, for example:

GROUND ALARM:
2 = LIFT DOWN

The effect of the machine digit value is displayed along
with its value. Above display would be selected if machine
was equipped with a ground alarm and you wanted it to
sound when lifting down. There are certain settings
allowed to install optional features or select the machine
model.

When selecting machine model to match machine size,
personality settings default to factory recommended
setting.

NOTE: Refer to Table 6-1, Personality Ranges/Defaults, and

in this Service Manual for the recommended factory
settings.

NOTE: Password 33271 gives you access to level 1, which

permits you to change all machine personality set-
tings.

JLG strongly recommends you do not change the ELEVA-
TION CUTBACK
setting.

CHANGING ELEVATION CUTBACK SETTING MAY ADVERSELY
AFFECT MACHINE PERFORMANCE.

Advertising