SECTION 6 - JLG CONTROL SYSTEM

6-52

– JLG Lift –

3121180

MOMENT:

Displayed if MODEL NUMBER = 7 or 8

(LB-IN) ACTUAL

XXXXXXXX

Current moment value

(LB-IN)
OVER

XXXXXXXX

Current over moment setpoint.

(LB-IN)
UNDER

XXXXXXXX

Current under moment setpoint.

CAL PT
UNDER

XXXXXXXX

Under moment value recorded during boom sensor calibration.

CAL PT
WIT YEL

XXXXXXXX

Yellow witness mark moment value recorded during boom sensor
calibration.

CAL PT
WIT GRN

XXXXXXXX

Green witness mark moment value recorded during boom sensor
calibration.

CYL PIN
RATIO

X.XXX

Current cylinder moment pin ratio of X and Y forces.

PIN
E FLAGS

0xXXXX

Current error flag status of cylinder moment pin.

sky welder

YES/NO

Status of Sky Welder selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

sky cutter

YES/NO

Status of Sky Cutter selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

sky glazier

YES/NO

Status of Sky Glazier selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

sky Bright

YES/NO

Status of Sky Bright selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

Pipe Racks

YES/NO

Status of Pipe Racks selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

Camera mount

YES/NO

Status of Camera Mount selected during boom sensor calibra-
tion. (Displayed if MODEL NUMBER = 7 or 8)

Table 6-6. Machine Diagnostics Parameters

Diagnostics

Submenu

(Displayed on

Analyzer 1

st

Line)

Parameter (Displayed

on Analyzer 2

nd

Line)

Parameter Value

(Displayed on Analyzer 2

nd

Line)

Description

Advertising