JLG 450A_AJ Series II Service Manual User Manual

Page 406

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-70

– JLG Lift –

3121180

MAIN LIFT PVG VALVE COMMAND
IMPROPER

Main boom lift pvg valve received invalid control system command.

TOWER LIFT PVG VALVE COMMAND
IMPROPER

Tower boom lift pvg valve received invalid control system command.

TOWER TELESCOPE PVG VALVE
COMMAND IMPROPER

Tower boom telescope pvg valve received invalid control system command.

MAIN LIFT PVG VALVE TIMEOUT

Main boom lift pvg valve has not received a position command in 250mS.

TOWER TELESCOPE PVG VALVE
TIMEOUT

Tower boom lift pvg valve has not received a position command in 250mS.

TOWER TELESCOPE PVG VALVE
TIMEOUT

Tower boom telescope pvg has not received a position command in 250mS.

MAIN LIFT PVG VALVE SETUP FAULT

Main boom lift pvg valve setup data is incorrect. Requires valve calibration.

TOWER LIFT PVG VALVE SETUP
FAULT

Incorrect tower boom lift pvg valve setup data. Requires valve calibration.

TOWER TELESCOPE PVG VALVE
SETUP FAULT

Incorrect tower boom telescope pvg valve setup data. Requires valve calibra-
tion.

MAIN LIFT PVG VALVE SENT UNREC-
OGNIZED FAULT

Main boom lift pvg valve sent unrecognized fault.

TOWER LIFT PVG VALVE SENT
UNRECOGNIZED FAULT

Tower boom lift pvg valve sent an unrecognized fault.

TOWER TELESCOPE PVG VALVE
SENT UNRECOGNIZED FAULT

Tower boom telescope pvg valve sent an unrecognized fault.

MAIN LIFT PVG VALVE PARAMETERS
INCORRECT

Main lift pvg valves spool data is incorrect. Requires valve calibration.

TOWER LIFT PVG VALVE PARAME-
TERS INCORRECT

The tower lift pvg valves spool data is incorrect. Requires valve calibration.

TOWER TELESCOPE PVG VALVE
PARAMETERS INCORRECT

The tower telescope pvg valves spool data is incorrect. Requires valve calibra-
tion.

MAIN LIFT PVG VALVE LOCATION
IMPROPER

Main lift pvg valve was hosed wrong or wiring incorrect during calibration.

TOWER LIFT PVG VALVE LOCATION
IMPROPER

Tower lift pvg valve was hosed wrong or wiring incorrect during calibration.

TOWER TELESCOPE PVG VALVE
LOCATION IMPROPER

Tower telescope pvg valve was hosed wrong or wiring incorrect during calibra-
tion.

MAIN LIFT PVG VALVE WIRING
INCORRECT

Power wire for main lift pvg valve not wired to that valve.

TOWER LIFT PVG VALVE WIRING
INCORRECT

Power wire for tower lift pvg valve not wired to that valve.

TOWER TELESCOPE PVG VALVE
WIRING INCORRECT

Power wire for tower telescope pvg valve not wired to that valve.

5/5

Flash code 5/5 indicates problems with vehicle engine RPM or the
encoder. Not reported during 2 second power-up.

8

SPEED SENSOR READING INVALID
SPEED

Diesel engines only. RPM pickup indicating a speed greater than 4000 RPM or
approximately 8875 Hz.

SPEED INPUT LOST

Diesel engines only. No RPM detected and oil pressure input reading above 8
PSI for more than three seconds. This is probably due to wiring problems at
ground module or a faulty speed sensor.

Table 6-8. Help Fault Codes, Displayed Faults, and Descriptions - S/N 0300066949 & S/N 1300000001 to Present

Fault Flash

Code

Communicated (Displayed on

Analyzer) Fault

Description

Priority

Advertising