JLG 450A_AJ Series II Service Manual User Manual

Page 398

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-62

– JLG Lift –

3121180

3/3

Flash code 3/3 indicates a driver problem. All driver faults are detected in
a similar manner. Open circuit faults are detected when analog feedback
reads too high and output is commanded off. Short to ground is detected
when analog feedback reads low and output is commanded on. Short to
battery is detected when analog feedback reads Vbat and output is
commanded off. Not reported during 2 second power-up. An EMS cycle
is required.

6

RIGHT FORWARD DRIVE PUMP
SHORT TO GROUND

Machines with a chassis module ONLY.

RIGHT FORWARD DRIVE PUMP
SHORT TO BATTERY

Machines with a chassis module ONLY.

RIGHT FORWARD DRIVE PUMP
OPEN CIRCUIT

Machines with a chassis module ONLY.

RIGHT REVERSE DRIVE PUMP
SHORT TO GROUND

Machines with a chassis module ONLY.

RIGHT REVERSE DRIVE PUMP
SHORT TO BATTERY

Machines with a chassis module ONLY.

RIGHT REVERSE DRIVE PUMP OPEN
CIRCUIT

Machines with a chassis module ONLY.

LEFT FORWARD DRIVE PUMP
SHORT TO GROUND

Machines with a chassis module ONLY.

LEFT FORWARD DRIVE PUMP
SHORT TO BATTERY

Machines with a chassis module ONLY.

LEFT FORWARD DRIVE PUMP OPEN
CIRCUIT

Machines with a chassis module ONLY.

LEFT REVERSE DRIVE PUMP SHORT
TO GROUND

Machines with a chassis module ONLY.

LEFT REVERSE DRIVE PUMP SHORT
TO BATTERY

Machines with a chassis module ONLY.

LEFT REVERSE DRIVE PUMP OPEN
CIRCUIT

Machines with a chassis module ONLY.

ALTERNATOR/ECM POWER SHORT
TO GROUND

HOUR METER SHORT TO GROUND

HOUR METER SHORT TO BATTERY

HORN SHORT TO GROUND

HORN OPEN CIRCUIT

HORN SHORT TO BATTERY

AUX POWER SHORT TO GROUND

AUX POWER OPEN CIRCUIT

AUX POWER SHORT TO BATTERY

GLOW PLUG SHORT TO GROUND

Machines with glowplugs configured ONLY.

GLOW PLUG OPEN CIRCUIT

Machines with glowplugs configured ONLY

GLOW PLUG SHORT TO BATTERY

Machines with glowplugs configured ONLY

LP LOCK SHORT TO GROUND

Machines with dual-fuel engines ONLY.

LP LOCK OPEN CIRCUIT

Machines with dual-fuel engines ONLY.

Table 6-8. Help Fault Codes, Displayed Faults, and Descriptions - S/N 0300066949 & S/N 1300000001 to Present

Fault Flash

Code

Communicated (Displayed on

Analyzer) Fault

Description

Priority

Advertising