JLG 450A_AJ Series II Service Manual User Manual

Page 27

Advertising
background image

SECTION 1 - SPECIFICATIONS

3121259

– JLG Lift –

1-11

21. Fuel Filter (Propane) - GM Engine

Interval - 3 Months or 150 hours of operation
Comments - Replace filter. Refer to Propane Fuel Filter
Replacement.

1.12 DRAINING PROPANE REGULATOR OIL

BUILD UP (PRIOR TO S/N 0300137808)

Operation oils may build in propane pressure regulator
primary and secondary chambers during normal use.
These oils are caused by poor fuel quality, fuel supply
chain contamination, or regional variation in fuel make
up. Significant oil buildup can effect fuel control system
operation. Refer to Section 1.11, Operator Mainte-
nance for main
tenance intervals. More frequent drain-
ing may be required if fuel supply is contaminated.

NOTE: Warm engine to operating temperature before drain-

ing For best results. this will allow oils to flow freely
from regulator.

1. Move equipment to a well ventilated area. Ensure

there are no external ignition sources.

2. Start engine and bring to operating temperature.

3. With engine running, close manual tank valve and

run engine out of fuel.

4. Push Emergency Stop when engine stops.

5. Disconnect electrical connection to LPG fuel tem-

perature sensor in auxiliary fuel port of the EPR.

6. Remove LPG fuel temperature sensor retainer clip

and sensor from regulator body.

NOTE: Have a small container ready to collect oil that drains

freely from regulator.

7. Drain all oil. Reinstall LPG fuel temperature sensor

and reconnect electrical connector.

8. Open fuel tank manual valve.

9. Pull out Emergency Stop and start engine. Verify all

connections are secure.

10. Dispose of any drained oil per local regulations in a

safe and proper fashion.

Advertising