JLG 450A_AJ Series II Service Manual User Manual

Page 386

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-50

– JLG Lift –

3121180

HI TILTED -

NO/YES

Displays status of hi tilt input. (Displayed if external tilt sensor is
configured)

AUX POWER

OP/CL

Displays the status of the auxiliary power switch input

HORN

OP/CL

Displays the status of the horn input

R FILTER

OP/CL

Displays the status of the return hydraulic filter by-pass switch.
Displayed ONLY if MODEL = 600 (Configuration digit = 3)

C FILTER

OP/CL

Displays measured status of charge pump filter bypass switch.
Displayed ONLY if MODEL = 600 (Configuration digit = 3)

JIB BLOCK

OP/CL

Jib block limit switch status. Not displayed if associated configura-
tion digit = 0

BASKET STOWD

YES/NO

Status of basket stowed mode. (Displayed if MODEL NUMBER =
7 or 8)

SOFT LIMIT

OP/CL

Status of soft touch limit switch. Not displayed if associated con-
figuration digit = 0

SOFT O/R

OP/CL

Status of soft touch override switch. Not displayed if associated
configuration digit = 0

GEN SET/WELDER

OP/CL

Generator/welder switch input status. Not displayed if associated
configuration digit = 0

LIGHTS

OP/CL

Head and tail light switch input status. Not displayed if associated
configuration digit = 0

BSK TILT1

XX.X

Indicated platform tilt angle. Displayed on models equipped with
Electronic Platform Leveling.

BSK TILT2

XX.X

Indicated platform tilt angle. Displayed on models equipped with
Electronic Platform Leveling.

AXLE RET SW

OP/CL

Status of axle extension user switches. (Displayed if MODEL
NUMBER = 7 or 8)

AXLE EXT SW

OP/CL

Status of axle retraction user switches. (Displayed if MODEL
NUMBER = 7 or 8)

AXLE LIM SW

RET/EXT

Status of axle extension limit switches. (Displayed if MODEL
NUMBER = 7 or 8)

DOS LIM SW

OP/CL

Drive Orientation System Limit Switch status. (Displayed if
MODEL NUMBER = 7 or 8)

DOS O/R SW

OP/CL

Drive Orientation System Override switch status. (Displayed if
MODEL NUMBER = 7 or 8)

CAPACITY SW

500/1000

Capacity selection switch status. (Displayed if MODEL NUMBER
= 7 or 8)

Table 6-6. Machine Diagnostics Parameters

Diagnostics

Submenu

(Displayed on

Analyzer 1

st

Line)

Parameter (Displayed

on Analyzer 2

nd

Line)

Parameter Value

(Displayed on Analyzer 2

nd

Line)

Description

Advertising