SECTION 5 - HYDRAULICS

5-32

– JLG Lift –

3121180

Placing Pump Back Into Service

1. If shop test stand is available, the following proce-

dure for testing rebuilt pumps is recommended:

a. Mount pump on test stand. Make sure proper

level of clean oil is available in reservoir. Check
suction line for leaks and obstructions.

b. Start pump and run for three minutes at zero

pressure.

c. Intermittently load pump to 500 P.S.I. for three

minutes.

d. Intermittently load pump to 1000 P.S.I. for three

minutes.

e. Intermittently load pump to 2000 P.S.I. for three

minutes.

f. Remove pump from test stand and check for

freeness of drive shaft. Check pump for signs of
external leakage.

2. If shop test stand is not available, the following pro-

cedure for testing rebuilt pumps is recommended:

a. For engine driven pumps, mount pump on

equipment and run pump at 1/2 engine speed at
zero pressure for three minutes.

b. Operate control valve and build pressure inter-

mittently for three minutes.

c. Increase engine speed to full throttle and build

pressure intermittently for three minutes.

d. Stop engine and check pump for external leaks.

5.3 VARIABLE PUMP

Ports and Pressure Gauges

Proper servicing of pumps and motors requires pressure
be measured and monitored at various points in the
hydraulic circuit. The Series 42 pump has several loca-
tions at which to take these measurements. The following
outlines show locations of various gauge ports. The fol-
lowing table shows recommended gauge size and fitting
size for each port.

NFPE Control

The 3-position FNR control, and electric and hydraulic
non-feedback proportional (NFPE and NFPH) controls are
non-feedback type controls. FNR and NFPE controls con-
sist of pump housing mounted modules. Hydraulic input
for NFPH is received through ports on top of pump [9/16–
18 SAE O-ring fitting].
The non-feedback controls are factory set. Control mod-
ules can be removed to clean ports and change O-rings.
Orifice plugs for the FNR and NFPE are located inside the
servo piston covers. Orifice plugs for the NFPH are
located in the NFPH ports. Orifice plugs may be cleaned
or replaced.

Table 5-4. Recommended Gauge Size

Gauge

Port

Name

Pressure

Measured

Recommended

Gauge Size

Fitting

PSI

Bar

M1 & M2

System

Pressure

Ports A & B

10000

600

9/16-18

ORF

M3

Charge

1000

60

3/4-16

ORF

M4 & M5

Servo

1000

60

9/16-18

ORF

L1 & L2

Case

500

35

1-1/16-12

ORF

S

Charge Pump

Inlet Vacuum

30 in. Hg Vac.

1

1-1/16-12

ORF