JLG 450A_AJ Series II Service Manual User Manual

Page 387

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121180

– JLG Lift –

6-51

osc axle p sw

OP/CL

Oscillating axle pressure switch status. (Displayed if
OSCILLATING AXLE = 1)

sky welder

YES/NO

Status of Sky Welder selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

sky cutter

YES/NO

Status of Sky Cutter status selected during boom sensor calibra-
tion. (Displayed if MODEL NUMBER = 7 or 8)

sky glazier

YES/NO

Status of Sky Glazier selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

sky Bright

YES/NO

Status of Sky Bright selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

Pipe Racks

YES/NO

Status of Pipe Racks selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)

Camera mount

YES/NO

Status of Camera Mount selected during boom sensor calibra-
tion. (Displayed if MODEL NUMBER = 7 or 8)

LOAD:

Not displayed if LOAD=NO, LENGTH=NO, and ANGLE=NO
(machine digits = 0)

LENGTH

OP /CL

Measured length, Not displayed if MODEL NUMBER = 7 or 8

ANGLE

OP / CL

Measured angle, Not displayed if MODEL NUMBER = 7 or 8

WEIGHT

XXXX%

Percentage of maximum calibrated weight on the platform. An
uncalibrated load cell reads 1000% Displayed if LOAD is not 0 and
LOAD TYPE is 0.

OK/OVERLOADED

LSS system status. Displayed if LOAD is not 0 and LOAD TYPE is
1.

Table 6-6. Machine Diagnostics Parameters

Diagnostics

Submenu

(Displayed on

Analyzer 1

st

Line)

Parameter (Displayed

on Analyzer 2

nd

Line)

Parameter Value

(Displayed on Analyzer 2

nd

Line)

Description